Product Overview
Introduction
It is an all-in-one kit that can be used in all successful GBR procedures since it is composed of various types of burs and bone tacks that are used for GBR procedures, and also driver and handle that are used for fixing the screw.
KIT

Specifications
Drill & Bur

Bone Chip Drill & Stopper
- This is to harvest or collect patient’s own bone using drills.
- Engage bone chip drill to engine and apply stopper.
- Components : Bone chip drill, stopper
- Recommendation RPM : 300~600 RPM


Bone Trimming Bur
- It is used to trim and contour alveolar bone for adaptation of barrier membrane or to remove granulation tissue of bony defect.


Cortical Perforation Bur
- It is used to promote stable bone regeneration by perforating cortical bone
- Recommendation RPM of the contra-angle bur : 1,200-1,500 RPMR
- Recommendation RPM of the straight bur : 30,000-40,000 RPM

Handle & Driver

Hex Driver (Ø0.9)
It is used when connecting the spacer and healing cap.


Universal Handle
The handle that is used by being connected to the bone screw driver, tack driver, and removal tip.

Bone Tack Instruments

Cortical Perforation Bur
- It is used for holding the bone tack while installing the implant.
- Separate the cover (blue part on the front) for connecting bone tack.


Bone Tack Removal Tip
It is used to remove the fixed tack.

Bone Screw & Tenting Screw Instruments

Pilot Drill
- It is used to form holes before installing the bone screw or bone tack when cortical bone is thick
- Recommendation RPM : 800~1,500 RPM


Cortical Perforation Bur
It is connected to the pilot drill and used to control drilling depth accurately while inserting the bone screw and tenting screw.


Bone Screw Driver (Handle)
It is used for holding the bone screw while installing the implant.


Bone Screw Driver (Handpiece)
- It is used for holding the bone screw while installing the implant.
- For screw removal, rotate it in opposite direction.
- Recommendation RPM : 40~50 RPM

Fixation Components (Separately sold products)

Bone Screw
It is a fixing screw that is used to fix the barrier membrane and it is fixed by using a designated screw driver.


Bone Tack
It is used to fix the barrier membrane and it is fixed by using a designated bone tack driver and mallet for increasing fixation.


Spacer
- It is used with a designated healing cap.
- A mediating structure that is connected to the implant in non-submerged type GBR.
- It is connected by using Ø 0.9 hex driver.
- Recommendation Torque Value : 12~15 NCm


Healing Cap
- It is used to fix barrier membrane on top of the spacer in non-submerged type GBR.
- It is connected by using Ø 0.9 hex driver.